产品中心
产品中心

CB/CVV series

浏览次数:0
所属分类:Carten
产品详情

CB/CVV Series Product Applications

This check valve series is intended for bulk gas distribution service where containment, cleanliness and purity are of the utmost importance, and makes this range an excellent consideration for:

  • High-purity gas distribution system control

  • Prevention of undesired reverse flow in high-purity systems

  • Superior containment and cleanliness for your most critical valve applications

  • Use with inert and most toxic gases

  • Most suitable for isolation applications


CB/CVV Series Product Features

  • Check Valve, Packless Compact Design

  • Ultra-High Purity Bar Stock Stainless SteelPCTFE Valve Construction

  • 10 Ra Max- Electropolished Surface Finish- Std (Optional Surface Finishes Available)

  • Purge Connections and Purge Valves are Integrated in Valve Body

  • Valve Body and Tube Stubs are Serialized for Material Certification





CB Construction Materials 

CB/CVV series

*See Ordering Code for other available-Valve FSM-MF Connection Ends-sizes 50o/750/1000.

** Viton® are registered trademarks of DuPont Company.


CB and CVV Series Technical Data

MATERIAL OF CONSTRUCTIONWetted Areas316L Stainless Steel, PCTFE, Nickel, *Viton®
Non-Wetted Areas316L Stainless Steel, Nickel Plated Brass (CVV 500)
MAXIMUM OPERATING PRESSURECVV SeriesVacuum-375 psig (25.8 bar)
CB SeriesVacuum-250 psig (17.2 bar)
MAXIMUM OPERATING TEMPERATURE*Viton® Seat – Std-15°F (-5°C) to 250°F (121°C)

Viton® is a registered trademark of DuPont Company.


VALVE MODELSBODY DATATECHNICAL DATATECHNICAL DATATECHNICAL DATAWEIGHTWEIGHT
             (Valve Sizes)                       (Tube/Body (Seat-Orifice) Sizes)                       Cv                      CP                       PFO                       (LBS)                     (KG)          
CVV 255Ø.250 / .500 (Ø.437 in. (Ø11.1mm)-Orifice)1.931.65 psig4.3 psig2.0(0.91)
CVV 500Ø.500 / .500 (Ø.437 in. (Ø11.1mm)-Orifice)1.931.65 psig4.3 psig2.0(0.91)
CVV755Ø.750 / .500 (Ø.437 in. (Ø11.1mm)-Orifice)2.001.65 psig5.0 psig2.1(0.95)
CB 751Ø.750 / 1.000 (Ø1.06 in. (Ø27.0mm)-Orifice)10.961.60 psig12.0 psig5.0(2.72)
CB 1000Ø1.000 / 1.000 (Ø1.06 in. (Ø27.0mm)-Orifice)15.211.60 psig12.0 psig6.0(2.72)
CB 1501Ø1.500 / 1.000 (Ø1.06 in. (Ø27.0mm)-Orifice)16.731.60 psig12.0 psig7.0(3.18)
CB 1502Ø1.500 / 2.000 (Ø2.12 in. (Ø53.8mm)-Orifice)42.430.60 psig6.0 psig19.0(8.62)
CB 2000Ø2.000 / 2.000 (Ø2.12 in. (Ø53.8mm)-Orifice)51.260.60 psig6.0 psig19.0(8.62)
CB 3002Ø3.000 / 2.000 (Ø2.12 in. (Ø53.8mm)-Orifice)78.000.60 psig6.0 psig21.0(9.53)
CB 3004Ø3.000 / 4.000 (Ø3.50 in. (Ø88.9mm)-Orifice)158.800.10 psig2.0 psig42.0(19.05)
CB 4000Ø4.000 / 4.000 (Ø3.50 in. (Ø88.9mm)-Orifice)165.500.10 psig2.0 psig40.0(18.14)
CB 6004Ø6.000 / 4.000 (Ø3.50 in. (Ø88.9mm)-Orifice)185.000.10 psig1.0 psig49.0(22.23)

(Cv) Flow Coefficient/(CP) Cracking Pressure/(PFO) Pressure to Full Open

HELIUM LEAK TESTInboard≤ 1 x 10⁻⁹ std.cc (atm) He / sec
Across the Seat≤ 1 x 10⁻¹⁰ std.cc (atm) He / sec
Outboard Pressure Test≤ 1 x 10⁻⁶ std.cc (atm) He / sec
CLEANLINESS AND PACKAGINGAssembled and tested in Class 100 Cleanroom. Purged and Final Packaged in Class 1 Cleanroom. Double-bag Packaging (2 mil nylon inner bag, 6 mil polyethylene outer bag) with Ultra-High Purity N₂ gas environment.
STANDARD FINISH10 Ra Max – Electropolished Surface Finish – Std (Optional surface finishes available)
NOTES AND OPTIONSTesting: Particle, Moisture, O₂, SEM, ESCA, and AES                                  
               Purge Connections – Valve Type/Location – Sizes .250 / .500                                    
               Valve Connection Ends – Inlet/Outlet Sizes .500/.750/1.000                                
                Valve Body Mounting Holes Std. Options:                                  
                1) CVV 500 – 10-32 UNF-2B                                    
               2) CB 1000 – .250-20 UNC-2B                                  
                3) CB 2000 – .375-16 UNC-2B                                    
                4) CB 4000 – .375-16 UNC-2B                                    
               Valve Body Flanged Ends – Rotatable                                  
                JIS Sizes (15A to 100A) Available – Consult Sales

Specifications are subject to change without notice.


CB and CVV Series Technical Dimensions

SERIES/SIZE (INCH)ABCDE
CVV 255Ø.250 (6.35mm)0.035 (0.89mm)0.72 (18.1mm)4.04 (102.6mm)9.87 (250.7mm)
CVV 500Ø.500 (12.7mm)0.049 (1.24mm)0.72 (18.1mm)3.04 (77.2mm)7.87 (199.9mm)
CVV 755Ø.750 (19.1mm)0.065 (1.65mm)0.72 (18.1mm)2.98 (75.7mm)7.75 (196.9mm)
CB 751Ø.750 (19.1mm)0.065 (1.65mm)0.75 (19.1mm)4.06 (10.3mm)11.61 (294.9mm)
CB 1000Ø1.000 (25.4mm)0.065 (1.65mm)0.75 (19.1mm)3.04 (77.2mm)9.61 (244.1mm)
CB 1501Ø1.500 (38.1mm)0.065 (1.65mm)0.75 (19.1mm)5.01 (127.3mm)13.51 (343.2mm)
CB 1502Ø1.500 (38.1mm)0.065 (1.65mm)1.25 (31.7mm)5.01 (127.3mm)15.48 (393.2mm)
CB 2000Ø2.000 (50.8mm)0.065 (1.65mm)1.25 (31.7mm)4.06 (103.1mm)13.58 (344.9mm)
CB 3002Ø3.000 (76.2mm)0.065 (1.65mm)1.25 (31.7mm)7.91 (200.9mm)21.28 (540.5mm)
CB 3004Ø3.000 (76.2mm)0.065 (1.65mm)2.13 (54.1mm)8.04 (204.2mm)23.47 (596.1mm)
CB 4000Ø4.000 (101.6mm)0.083 (2.1mm)2.13 (54.1mm)4.20 (106.7mm)15.79 (401.1mm)
CB 6004Ø6.000 (152.4mm)0.109 (2.7mm)2.13 (54.1mm)11.78 (299.2mm)30.95 (786.1mm)

NOTE 1:All tolerances are +0.06 in.(±1.52mm) unless otherwise stated.

NOTE 2: Dimensional drawings shown are for reference only. Please contact CARTEN® for customer drawings.

 

CB and CV Series Typical Valve Dimensions (1/4" to 6")

 CB/CVV series

CB and CVV Series Ordering Code

 CB/CVV series